Floor Partition Fire Rating Stantards
Corridor walls permitted to have a 1 2 hour fire resistance rating by table 1018 1 applies to r occupancies with sprinkler systems.
Floor partition fire rating stantards. Fire partitions shall have a fire resistance rating of not less than 1 hour. Fire resistance performance is based on complete systems such as a partition wall ceiling membrane or floor therefore plasterboard cannot be considered on their own in terms of fire resistance. Oshpd fire resistive standard details 10 8 2014 10 36 38 am drawing index 2 of 2 frx 01 drawing index revisions fr3 penetration details for fire resistive rated gypsum board assemblies fr3 00 not used fr3 01 recessed m e p. The total fire rating is determined by adding each component to reach a minimum total of 60 minutes.
Fire rated wall floor and ceiling assemblies provide the necessary fire and smoke barriers to create compartmentalization during a fire safeguarding against the spread of fire and smoke within a building or to and from a building. Cabinet in rated partition fr3 02 hollow metal door frame at 1 hour rated wall fr3 03 hollow metal door frame at 2 hour. Fire protection rating is calculated from the flame side of the assembly and of course some assemblies have multiple flame sides. The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels.
Fire resistance durations are established from the guidance to standards 2 1 to 2 15. Dwg pdf fire resistive interior wall joints comprehensive drawing 2 5 16 2 hr 2 hr top and bottom of wall joint for concrete over metal deck simplified drawing 2 29 16 2 hr 2 hr top and bottom of wall joint for flat deck simplified drawing 6 7 16 dwg pdf non fire rated smoke partition cp 506 smoke and acoustic sealant comprehensive. These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies. These assemblies need to meet fire and smoke safety and environmental sustainability requirements.
Which partition types provide high acoustic performance with minimum impact to space. Reference throughout this document to a short medium or long fire resistance duration will be satisfied by following the guidance in the table to this annex titled fire resistance duration for common building elements or components. Your wood framing members are required to be not more than 16 on center. Astm e119 standard test methods for fire tests of building construction and materials is the test standard for determining the fire resistance rating of partitions floor ceiling assemblies roof ceiling assemblies beams and columns.