Floor Loading Calculation Kpa

A typical wood frame floor covered with carpet or vinyl flooring has a dead load of about 8 pounds per square foot.
Floor loading calculation kpa. Factory floor load is 20 kn m2. 1 response report abuse. 1 0 m 2 of floor the loading over the 1 0 m area is 2 0 kpa. Design parameters armed with this information it becomes easier to understand why a deck or balcony might need to be designed to a higher floor loading than a domestic floor.
Calculation of floor load rating required for heavy machine. All unfixed items in a building such as people and furniture result in a live load on the structure. However you should consider the weight of the raised floor in the floor loading formula. Area of floor 6 0 m x 4 0 m 24 m 2 live load rating of a house 1 5 kpa therefore live load of floor 24 m 2 x 1 5 kpa 36 kn.
A floor loading assessment is the evaluation of the concrete subfloor not the raised floor. 500 kg m 2 is typical for office storage space and similar. 2attic loads may be included in the floor live load but a 10 psf attic load is typically used only to size ceiling joists adequately for access purposes. The dead load on a floor is determined by the materials used in the floor s construction.
10 years ago 3 months left to answer. The raised floor weight plus the cable weight adds 50 kg m 2 10 lb ft 2 uniformly across the total area used in calculations and is included in the 340 kg m 2 70 lb ft 2. Imposed loads varies from approximately 1 5 kn m 2 153 kg m 2 in domestic buildings to approximately 10 kn m 2 1053 kg m 2 in heavy industrial areas. If there s wall board covered ceiling suspended from the underside of that floor the dead load increases to about 10 pounds per square foot.
Factory space is 10 x 10 m2. For the best answers search on this site https shorturl im aw2kk. However if the attic is intended for storage the attic live load or some portion should also be considered for the design of. They are likely to carry a large number of people at one time such as in social situations.
Need to cal how much floor load needed to place a 14 tons rolling mill. Live loads are exerted in the vertical plane. Machine foot print is 8 x 12 ft. The floor loading should not exceed 240 kg m 2 50 lb ft 2 with a partition allowance of 100 kg m 2 20 lb ft 2 for a total floor load rating of 340 kg m 2 70 lb ft 2.
And if you don t calculate correctly you ll have an expensive repair on your hands.