Floor Level Exit Signs

Group a occupancies that are protected throughout.
Floor level exit signs. These should be positioned in every corridor and meeting room so that everyone knows the quickest safest and fastest way out of a building in an emergency. According to both the international building code and the international fire code floor level exit signs are required in buildings with group r 1 occupancy. This is why it is a good idea to use floor level signs in conjunction with other fire and emergency exit signage. 1011 2 floor level exit signs in group r 1.
For example evacuation maps. The bottom of the sign shall be not less than 6 in. Floor level exit signs provide critical information essential to egress safety. In various circumstances an exit sign posted above an emergency exit door is sufficient but there are certain situations where floor proximity exit signs are also required.
Where exit signs are required in group r 1 occupancies by section 1011 1 additional low level exit signs shall be provided in all areas serving guest rooms in group r 1 occupancies and shall comply with section 1011 5. Where exit signs are required by chapter 10 additional approved low level exit signs which are internally or externally illuminated photoluminescent or self luminous shall be provided in all interior corridors of group a e i and r 2 1 occupancies and in all areas serving guest rooms of hotels in group r division 1 occupancies. 150 mm but not more than 18 in. According to the international code council when it comes to placement of the low level exit sign the bottom of the low level exit sign shall be not less than 10 inches 254 mm nor more than 12 inches 305 mm above the floor level while the nfpa 101 life safety code section 7 10 1 6 permits the bottom of low level exit signs to be.
455 mm above the floor. As part of a photoluminescent egress pathmarking system floor identification signs fid enhance both egress speeds and safety. The bottom of the sign shall be not less than 10 inches 254 mm nor. Such signs shall be located near the floor level in addition to those signs required for doors or corridors.
Los angeles building code 10 means of egress 1013 exit signs 1013 2 floor level exit signs in group r 1 1013 8 means of egress path marking or no higher than 8 inches 203 mm above the floor level in all interior rated exit corridors of unsprinklered group a r 1 and r 2 occupancies. For exit doors the sign shall be mounted on the door or adjacent to the door with the nearest edge of the sign within 4.