Floor Framing Section Foundation Wall

Joist spans and spacing are determined by engineering that is published by the manufacturer.
Floor framing section foundation wall. Their exact construction and connection with the wall studs depend on the method of framing that is utilized. All framing sections should be cross referenced on the building plans using the floor foundation and or roof framing views. Slab on grade foundation with floor and footing poured as one unit and the floor at or. At the foundation level floor joists rest directly on a sill that is treated with preservative so that contact with the foundation will not promote termites or rot.
Chapter 3 foundation walls and piers 8 poured concrete walls 8 concrete block walls 9 masonry construction for crawl spaces 11 sill plate anchors 11 reinforcing in poured walls 11 masonry veneer over frame walls 12 notch for wood beams 12 protection against termites 12 chapter 4 concrete floor slabs on ground 15. This article teaches you how to build a floor for a house on a concrete foundation. Framing for floor openings a staircase is essential for commuting between floors but it creates an opening in the second floor so you can t run the joists from one side of the house to the other without interruption. Figure 3 4 interior braced wall on floor framing.
This framing system can also be used for framing storage shed floors this floor framing system is typical over basements and crawl spaces. Sheathing with the wall resting on 2x10s which in turn rest on an 8 in. The foundation wall may be an integral part of the load bearing design of the building carrying column and floor loads from above either as distributed loads on the wall or point loads on pilasters integral to the wall system. An interior braced wall line to have a foundation the foundation depth along that interior wall must be at least 18 inches below the top of the slab as shown in figure 3 5.
Framing a floor using i joists. The main consequence of not providing a continuous. I joist floor framing i joist sprinkler mounting lateral load connections moisture management panel floor construction panel roof construction panel wall construction special systems structural insulated panels wall bracing. Illustrations depict conventional wood construction.
In our example 2x8s are spaced every 16 in. Framing member widths and spacing as well as sheathing thickness depend mostly on backfill height. Type floors foundation roofs. The deeper into the ground the stronger the wall needs to be.