Electrical Code Floor Receptacle

You can t just mount a regular wall outlet in the floor.
Electrical code floor receptacle. The national electrical code requires floor outlets to be a part of an approved assembly consisting of a metal box gasket seal special receptacle and strong cover plate with a moisture proof cover. I would like to install a 15 amp floor outlet. Installing a floor outlet electrical question. What is the difference between a floor outlet and a wall outlet.
I would like to install a 15 amp floor outlet are their specific codes that involve floor outlets. Electrical codes are in place to protect you the homeowner. 2 floor receptacle outlets. What are the code rules for using floor receptacles to meet the receptacle wall outlet requirements in a dwelling wall space.
Introduction to electrical codes for outlets and receptacles nec 210 7 receptacle outlets shall be of the grounding type be effectively grounded and have proper polarity. Any floor receptacle within 18 inches of the wall counts the same as a wall outlet but it must be the proper kind of floor outlet and not a standard duplex receptacle. The national electrical code defines a wet location as an area that is subject to saturation with water or other liquids and unprotected locations exposed to the weather. A meeting room that is at least 3 7 m 12 ft wide and that has a floor area of at least 20 m 2 215 ft 2 shall have at least one receptacle outlet located in the floor at a distance not less than 1 8 m 6 ft from any fixed wall for each 20 m 2 215 ft 2 or major portion of floor space.
Most local codes are based on the national electrical code nec a document that lays out required practices for all aspects of residential and commercial electrical. There is no danger to installing 15 amp outlet receptacles on a 20 amp circuit in fact this is the standard practice but under no circumstances should a 20 amp receptacle be installed on a 15 amp circuit. These general guidelines will give you the basics of what electrical inspectors are looking for when they review both remodeling projects and new installations. We have a 2 raised floor on a concrete slab.
A 20 amp receptacle is designed to accept the special plug on heavier use appliances and if such an appliance plugs into a 15 amp circuit there is a danger of drawing too much power and. Most of the sources we have reviewed for details about the required height of electrical receptacles above the floor see mike holt s forum for example assert that there is no national electrical code nec specification of the height of wall mounted electrical receptacles in homes. The first time someone stepped on it it would break. A floor receptacle outlets are not counted as the required receptacle wall outlet if they are located more than 18 in.