The gross floor area shall not.
Egress floor area under sloped ceiling. The number of occupants shall be computed at the rate of one occupant per unit of area as prescribed in table 1004 1 2 for areas without fixed seating the occupant load shall be not less than that the number determined by dividing the floor area under consideration by the occupant load factor assigned to the function of the space as set forth in table 1004 1 2. Sloped ceilings in accordance with section 1207 2. For rooms with sloped ceilings at least 50 percent of the required floor area of the room must have a ceiling height of at least 7 feet and no portion of the required floor area may have a ceiling height of less than 5 feet. The floor area within the inside perimeter of the.
1003 6 means of egress continuity. Have a minimum opening width of at least 20 inches. Allowable projections in accordance. Protruding objects are permitted to extend below the minimum ceiling height required by section 1003 2 where a minimum headroom of 80 inches 2032 mm is provided over any circulation paths including walks corridors aisles and passageways.
Have a minimum opening height of at least 24 inches. Have a sill height of no more than 44 inches above the attic floor level. In other than group i 2 and group i 2 1 occupancies not more than 50 percent of the ceiling area of a means of egress shall be permitted to be reduced. Than that number determined by dividing the floor area under consideration by the occupant load factor assigned to the function of the space as set forth in table 1004 1 2.
Where the slope is greater than. More than 50 percent of the ceiling area of a means of egress shall be reduced in height by protruding objects. The means of egress shall have a ceiling height of not less than 7 feet 6 inches 2286 mm 7 feet 2134 mm above the finished floor. Sloped ceilings in accordance with section 1208 2.
Attic egress openings must. 305 mm exist in the means of egress sloped surfaces shall be used. Have a minimum net opening area of at least 5 7 square feet. Sloped ceilings in accordance with 780 cmr 1208 2.
Ceilings of dwelling units and sleeping units wi thi n r esid enti al oc cup anc ie s in a ccor da nc e wi th 780 cmr 1208 2. The floor area of a building or portion thereof not provided with surrounding exterior walls shall be the usable area under the horizontal projection of the roof or floor above. R310 1 emergency escape and rescue openings required.